Labelling Cryo Straws and Vials for Long-Term Storage: Labels That Survive Liquid Nitrogen, What to Print and How to Check
Almost every sample mix-up investigation in a cryostore ends at the same place: a label that could no longer be read, a label that fell off, or a label that was right on the straw but wrong in the record. The labelling itself rarely gets the attention it deserves because it looks like the easy part. In practice it is the one control that has to keep working for the entire storage life of a sample, often ten years or more, through repeated exposure to liquid nitrogen, condensation, frost and handling with gloved hands.
This guide is written for embryologists, biobank managers and laboratory staff who are responsible for what goes into long-term storage. It covers what actually fails, which labelling methods survive liquid nitrogen, what to print on the label, and how to build checks that catch errors before they become incidents.
Why labels fail in liquid nitrogen
Most labelling failures come from using a material or method designed for room temperature or a standard freezer. The common failure modes are:
Adhesive failure. Ordinary paper and many plastic labels rely on adhesives that turn brittle at cryogenic temperatures. The label stays put on day one, then lifts at the edge after a few cycles of removal and return, and eventually detaches in the canister.
Labels applied to a cold or wet surface. Even a cryogenic label will not bond properly to a tube that is already cold, frosted or damp. Labelling has to happen at room temperature on a clean, dry surface before the sample is frozen.
Ink that smears or fades. Standard marker pens can rub off when frost forms and is wiped away, or run when condensation forms on a tube taken out of storage. Alcohol used to wipe surfaces will remove many inks completely.
Labels that are too small to read. Straws and small vials leave very little space. Handwriting shrunk to fit becomes illegible, especially through frost, behind a face shield and in low light at the neck of a vessel.
Labels that do not match the record. The physical label can be perfect and still be wrong if it was printed for the wrong patient, applied to the wrong device, or never cross-checked with the database.
Choosing a labelling method that survives storage
There are three practical routes, and many laboratories use a combination.
Printed cryogenic labels. Thermal transfer printing on labels specifically made for cryogenic use gives the most consistent and legible result. The Brady BMP21 label printer is compatible with Brady B-595 low-shrink vinyl labels, which are designed to withstand temperature change, moisture and handling, and it is portable enough to use at the bench where samples are prepared. Printing removes handwriting errors and makes it straightforward to add a barcode.
Cryogenic markers. Where printing is not practical, a dedicated cryomarker is designed for marking surfaces that will go to ultra-low temperatures. Marking should still be done at room temperature on a dry surface, and the ink allowed to dry before the item is cooled.
Colour coding and physical identifiers. Colour does not replace a written identifier, but it speeds up retrieval and reduces handling time in the vessel. Cryocane coders give a flat surface for marking at the top of a cane, plastic identification tabs fit onto cryocanes and visotubes, and ID rods for visotubes come in a range of colours. A laboratory might assign colours by patient group, sample type or storage year, as long as the scheme is written down and used consistently.
What to put on the label
The label must allow the sample to be identified without reference to anything else, and it must match the record exactly. A sensible minimum for a straw, vial or device is:
At least two unique identifiers for the patient or donor, such as full name and a unique laboratory or clinic number. A sample or device number that is unique within the laboratory. The date of freezing. The sample type, for example oocytes, embryos, sperm or a cell line. A barcode carrying the same identifiers, where the laboratory uses electronic witnessing or inventory software.
Avoid abbreviations that only one person understands, and avoid relying on position in a canister as the only identifier. Positions change when stores are reorganised or samples are moved to a new vessel.
Labelling the container as well as the sample
Every level of the storage hierarchy should carry an identifier that matches the inventory: the device or straw, the goblet or visotube, the cane, the canister and the vessel itself. If a straw is ever found loose in a canister, the labels on the surrounding containers are what allow it to be traced. The BMP21 can also be used to label storage vessels and sample containers, so that vessel and canister labels match the system used for the samples.
Building checks into the process
A good label is only half of the control. The other half is making sure the right label goes on the right sample, and that the record matches.
Print and label one patient at a time. Having labels for several patients on the bench at once is a well-recognised route to mix-ups.
Witness at the critical steps. In UK fertility laboratories, the HFEA Code of Practice sets out requirements for witnessing and identification of gametes and embryos. Whether a laboratory uses manual double witnessing or an electronic system, the check should confirm that the identifiers on the label match the patient, the dish and the record before freezing, and again at thaw.
Check legibility before freezing. Read every printed or written label back before the sample goes into the vapour or liquid phase. Once it is in the vessel, correcting a label means unnecessary handling.
Reconcile the inventory regularly. Periodic audits that compare the physical contents of a canister with the database find labelling and recording errors while they can still be corrected. An annual cryo storage self audit is a natural point to include a labelling review.
Handling labelled samples without damaging the label
Labels are often damaged by handling rather than by cold. Keep removal from the vessel brief, avoid rubbing frost off labels with gloved fingers, do not wipe labelled items with alcohol, and use forceps or tongs rather than gripping straws across the label area. When samples are moved between vessels, or out to another clinic in a dry shipper, check the labels on arrival before the samples go into their new location.
When a label is unreadable or missing
Every laboratory should have a written procedure for a sample that cannot be positively identified. That usually means quarantining the item, recording the incident, investigating using the surrounding container labels and the inventory record, and never relabelling from memory. In regulated settings the incident will also need to be reported through the appropriate route.
Getting the labelling kit right
If you are setting up a new cryostore, moving to printed labels or reviewing an existing system, tell us what you store, the devices and containers you use, roughly how many samples you label each week and whether you use barcodes. We can put together printers, labels, markers and colour coding from our storage accessories range, with next day delivery on standard UK stock and shipping to laboratories, clinics and biobanks worldwide.
More from Cryolab
Tissue Bank Storage: Which Tissues Need Liquid Nitrogen, Which Do Not, and How to Lay Out the Store
A tissue bank runs several cold chains at once. This guide covers which tissues need liquid nitrogen vapour, how to separate quarantine from released stock, and how to size the vessels.
Cell Cryopreservation: A Cell Freezing Protocol From Flask to Vapour Phase, and Where Each Step Goes Wrong
A standard cell freezing protocol for mammalian cell lines, from harvest to vapour phase storage and thawing, with the equipment behind each step.